Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add filters








Language
Year range
1.
Acta Pharmaceutica Sinica B ; (6): 3156-3166, 2022.
Article in English | WPRIM | ID: wpr-939961

ABSTRACT

d-α-Tocopheryl polyethylene glycol 1000 succinate (TPGS, also known as vitamin E-TPGS) is a biodegradable amphiphilic polymer prepared by esterification of vitamin E with polyethylene glycol (PEG) 1000. It is approved by the US Food and Drug Administration (FDA) and has found wide application in nanocarrier drug delivery systems (NDDS). Fully characterizing the in vivo fate and pharmacokinetic behavior of TPGS is important to promote the further development of TPGS-based NDDS. However, to date, a bioassay for the simultaneous quantitation of TPGS and its metabolite, PEG1000, has not been reported. In the present study, we developed such an innovative bioassay and used it to investigate the pharmacokinetics, tissue distribution and excretion of TPGS and PEG1000 in rat after oral and intravenous dosing. In addition, we evaluated the interaction of TPGS with cytochromes P450 (CYP450s) in human liver microsomes. The results show that TPGS is poorly absorbed after oral administration with very low bioavailability and that, after intravenous administration, TPGS and PEG1000 are mainly distributed to the spleen, liver, lung and kidney before both being slowly eliminated in urine and feces as PEG1000. In vitro studies show the inhibition of human CYP450 enzymes by TPGS is limited to a weak inhibition of CYP3A4. Overall, our results provide a clear picture of the in vivo fate of TPGS which will be useful in evaluating the safety of TPGS-based NDDS in clinical use and in promoting their further development.

2.
Acta Pharmaceutica Sinica B ; (6): 228-234, 2018.
Article in English | WPRIM | ID: wpr-690916

ABSTRACT

Because many therapeutic agents are contaminated by epimeric impurities or form epimers as a result of metabolism, analytical tools capable of determining epimers are increasingly in demand. This article is a proof-of-principle report of a novel DMS-MS/MS method to separate and simultaneously quantify epimers, taking PGF2 and its 8-epimer, 8--PGF2, as an example. Good accuracy and precision were achieved in the range of 10-500 ng/mL with a run time of only 1.5 min. Isopropanol as organic modifier facilitated a good combination of sensitivity and separation. The method is the first example of the quantitation of epimers without chromatographic separation.

SELECTION OF CITATIONS
SEARCH DETAIL